المنتجات

اللوحات التكرارية

  • MR-2300-LCDR Remote LCD Annunciator

    Features

    • Listed to UL 864, 9th edition.Available in six and twelve zone models
    • Available in LED and LCD Display configurations
    • LCD Display versions are equipped with a 2 line by 20 character back-lit LCD display and numerical
    keypad
    • Integrated UDACT/Digital Communicator on select models
    • Front panel and PC programmable
    • LED Display versions are front panel (using CFG-300 configuration tool) and PC programmable
    • Remote upload/download capabilities
    • Base panel is equipped with Class “B” (Style “B”) initiating circuits which may be configured as Class “A” (Style “D”) using a Class “A” converter module
    • Initiating circuits may be configured as Alarm, Verified Alarm, Waterflow Alarm, Sprinkler Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble- Only
    • Base panel is equipped with Class “B” (Style “Y”) indicating circuits which may be configured as Class “A” (Style “Z”) using a Class “A” signal converter module
    • Audible signals may be configured for Steady, Temporal Code, California Code and March Time
    • Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes
    • Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor,
    Gentex, Faraday and Wheelock
    • Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble
    • Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test
    • Subsequent Alarm, Supervisory, and Trouble operation
    • RS-485 Interface for Remote LED Annunciators, LCD Annunciators and Remote Smart Relay Modules
    • Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events
    • 5 Amp Power Supply
    • Optional modules for additional internal relay circuits and City Tie/Polarity Reversal
    • Optional trim rings for semi-flush mounting

    Learn More
  • RAM-1016TZDS Main Annunciator Chassis

    Features

    • Listed to UL 864, 9th edition• Available in six and twelve zone models
    • Available in LED and LCD Display configurations
    • LCD Display versions are equipped with a 2 line by 20 character back-lit LCD display and numerical keypad
    • Integrated UDACT/Digital Communicator on select models
    • Front panel and PC programmable
    • LED Display versions are front panel (using CFG-300 configuration tool) and PC programmable
    • Remote upload/download capabilities
    • Base panel is equipped with Class “B” (Style “B”) initiating circuits which may be configured as Class “A” (Style “D”) using a Class “A” converter module
    • Initiating circuits may be configured as Alarm, Verified Alarm, Waterflow Alarm, Sprinkler Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble- Only
    • Base panel is equipped with Class “B” (Style “Y”) indicating circuits which may be configured as Class “A” (Style “Z”) using a Class “A” signal converter module
    • Audible signals may be configured for Steady, Temporal Code, California Code and March Time
    • Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes
    • Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock
    • Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble
    • Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test
    • Subsequent Alarm, Supervisory, and Trouble operation
    • RS-485 Interface for Remote LED Annunciators, LCD Annunciators and Remote Smart Relay Modules
    • Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events
    • 5 Amp Power Supply
    • Optional modules for additional internal relay circuits and City Tie/Polarity Reversal
    • Optional trim rings for semi-flush mounting

    Learn More
  • RAM-1032TZDS Main Annunciator Chassis

    Features

    Fire Alarm Control:
    • One expandable to nine Intelligent Signaling Line Circuits (SLC)
    • Modular design
    • Each SLC is capable of supporting 159 Analog Sensors and 159 Addressable Modules which can be wired in Style 6 or 7 (Class A) or Style 4 (Class B)
    • Four Style Z/Y (Class A/B) Notification Appliance Circuits
    rated at 1.7 Amps each
    • System has the ability to mix CLIP and AP devices on the same loop
    • Large 4 by 20 character Back-lit LCD Display with user friendly menu
    • Supported languages: English, French, Arabic* and Hebrew* (*960 character back-lit LCD display only)
    • Correlatable Switch Inputs which allow for multi-functional outputs
    • Four Status Queues with selector switches and LEDs for Alarm, Supervisory, Trouble and Monitor
    • Auxiliary relay contacts for Common Alarm, Common Supervisory and Common Trouble
    • Group bypass with built-in false alarm prevention technology
    • RS-232 output for remote system printer or CRT
    • Two Event History Logs comprised of a 6000 event alarm history log for alarm related events and a 6000 event log for all events
    • Supports three configuration files (current, previous and next configuration) with “hot swap” support
    • Supports Conventional Hardwire Adder Modules
    • Built-in One Man Walk Test operation
    • Configurable for Canadian Two Stage operation
    • Configurable for Coded Operation
    • Capability to adjust Intelligent Smoke Detector sensitivity levels
    • Real time 3D graphical monitoring and control using Open Graphic Navigator™
    • BACnet support
    • Supports Boolean logic functions
    • Built-in Ethernet port
    • Remote diagnostics via a built-in web server
    • UL listed for Smoke Control

    Network Features:
    • Up to 63 nodes
    • Peer-to-peer network communications
    • Style 4 (Class B) or Style 6 or 7 (Class A) wiring configuration
    • Proprietary Arcnet Network Communications protocol
    • Supports copper and/or fiber optic network cable

    Learn More
  • RAX-1048TZDS Main Annunciator Chassis

    Features

    Fire Alarm Control
    • One expandable to nine Intelligent Signaling Line Circuits
    (SLC)
    • Modular design
    • Each SLC is capable of supporting 159 Analog Sensors and
    159 Addressable Modules which can be wired in Style 6 or
    7 (Class A) or Style 4 (Class B)
    • Four Style Z/Y (Class A/B) Notification Appliance Circuits
    rated at 1.7 Amps each
    • System has the ability to mix CLIP and AP devices on the
    same loop
    • Large 4 by 20 character Back-lit LCD Display with user
    friendly menu
    • Supported languages: English, French, Arabic* and Hebrew*
    (*960 character back-lit LCD display only)
    • Correlatable Switch Inputs which allow for multi-functional
    outputs
    • Four Status Queues with selector switches and LEDs for
    Alarm, Supervisory, Trouble and Monitor
    • Auxiliary relay contacts for Common Alarm, Common
    Supervisory and Common Trouble
    • Group bypass with built-in false alarm prevention technology
    • RS-232 output for remote system printer or CRT
    • Two Event History Logs comprised of a 6000 event alarm
    history log for alarm related events and a 6000 event log
    for all events
    • Supports three configuration files (current, previous and next
    configuration) with “hot swap” support
    • Supports Conventional Hardwire Adder Modules
    • Built-in One Man Walk Test operation
    • Configurable for Canadian Two Stage operation
    • Configurable for Coded Operation
    • Capability to adjust Intelligent Smoke Detector sensitivity
    levels
    • Real time 3D graphical monitoring and control using Open
    Graphic Navigator™
    • BACnet support
    • Supports Boolean logic functions
    • Built-in Ethernet port
    • Remote diagnostics via a built-in web server
    • UL listed for Smoke Control
    Network Features
    • Up to 63 nodes
    • Peer-to-peer network communications
    • Style 4 (Class B) or Style 6 or 7 (Class A) wiring configuration
    • Proprietary Arcnet Network Communications protocol
    • Supports copper and/or fiber optic network cable

    Learn More
  • MMX-BB-1001R Semi-Flush Backbox for Series 1000 Annunciators

    Features

    • Provide the same functions as the main display on the MMX Series fire alarm control units
    • Available in two models
    – Large 80 character (4×20) back-lit LCD display
    – 960 character (24×40) graphical back-lit LCD display
    • Connect to any node to annunciate the full network system or selected network nodes
    • Do not take up a node address
    • Easy to use menu system complete with a directional keypad and switches
    • Four Status Queues with selector switches and LEDs for Alarm, Supervisory, Trouble and Monitor  to sort events
    • Support programmable modules and annunciator modules
    • RAXN-LCDG displays nine events per page with each event displayed over 2 lines with 40 characters per line
    • RAXN-LCDG meets Canadian ULC sequential display requirements
    • Both models can mount in a MMX Series annunciator enclosure

    Learn More
  • MR-2300-LCDR Remote LCD Annunciator

    المميزات

    •  تشتمل  اللوحة التكرارية  MR-2300-LCDR على شاشة عرض LCD بسعة 2 خط × 20 حرفًا.
    •  تشتمل اللوحة التكرارية MR-2300-LCDR على مفاﺗﯾﺢ اﻟﺗﺣﮐم ﻹﻋﺎدة ﺗﻌﯾﯾن اﻟﻧظﺎم ، لإسكات الإشارة، مفتاح للتدريب على خطة الإخلاء في حالة حدوث حريق (سيناريو الحرﯾق) والمعلومات ﺑﺎﻹﺿﺎﻓﺔ إﻟﯽ ﻟوﺣﺔ ﻣﻔﺎﺗﯾﺢ رﻗﻣﯾﺔ ﻟﻟوﺻول إﻟﯽ ﻘﺎﺋﻣﺔ الوظائف.
    •  يمكن تعطيل وظائف التحكم على أساس كل وظيفة.
    •  يحتوي MR-2300-LCDR على مؤشرات LED لتبين ما إذا كان التيار الكهربائي واصل للدائرة و الإنذار و المراقبة و الخلل و فشل النظام.
    •  تأتي اللوحة التكرارية  MR-2300-LCDR داخل صندق أحمر وقفل ومفتاح CAT-30.

    Learn More
  • شاسيه اللوحات التكرارية الرئيسي RAM-1016TZDS

    المميزات

    •  تحتوي اللوحة التكرارية RAM-1016TZDS على 16 لمبة بيان .
    •  تحتوي اللوحة التكراريةRAM-1016TZDS  على لمبتين بيان إحداهما تضئ اللون الأحمر في حالة الإنذار و الأخرى تضئ باللون الأصفر البرتقالي في حالة الإشراف و لمبات بيان منفردة عند حدوث أي خلل .
    •  يحتوي RAM-1016TZDS على مؤشرات LED لتبين ما إذا كان التيار الكهربائي واصل للدائرة و الإنذار و المراقبة و الخلل و فشل النظام و إعادة تعين النظام و لمبة اختبار مفتاح للتدريب على خطة الإخلاء في حالة حدوث حريق (سيناريو الحرﯾق) و إسكات الإزعاج الصوتي .
    •  يمكن تعطيل وظائف التحكم على أساس كل وظيفة.
    •  يتم تثبيت اللوحة التكرارية  RAM-1016TZDS داخل صندوق  MMX-BB-1001R.

    Learn More
  • شاسيه اللوحات التكرارية الرئيسي RAM-1032TZDS

    المميزات

    •  تحتوي اللوحة التكرارية RAM-1032TZDS على 32 لمبة بيان .
    •  تحتوي اللوحة التكراريةRAM-1032TZDS  على لمبتين بيان إحداهما تضئ اللون الأحمر في حالة الإنذار و الأخرى تضئ باللون الأصفر البرتقالي في حالة الإشراف و لمبات بيان منفردة عند حدوث أي خلل .
    •  يحتوي RAM-1032TZDS على مؤشرات LED لتبين ما إذا كان التيار الكهربائي واصل للدائرة و الإنذار و المراقبة و الخلل و فشل النظام و إعادة تعين النظام و لمبة اختبار مفتاح للتدريب على خطة الإخلاء في حالة حدوث حريق (سيناريو الحرﯾق) و إسكات الإزعاج الصوتي .
    •  يمكن تعطيل وظائف التحكم على أساس كل وظيفة.
    •  يتم تثبيت اللوحة التكرارية  RAM-1032TZDS داخل صندوق  MMX-BB-1001R أو BB-5000.

    Learn More
  • شاسيه اللوحات التكرارية الرئيسي RAX-1048TZDS

    المميزات

    •  تشتمل وحدة RAX-1048TZDS LED القابلة للبرمجة على 48 لمبة بيان LED ثنائية اللون قابلة للبرمجة أيضا.
    •  يتم اتصال وحدة RAX-1048TZDS بوحدة التحكم الرئيسية RAXN-LCD أو RAM-1032TZDS عند تركيبها عن بعد.
    •  يتم تثبيت وحدة RAX-1048TZDS في المكان المحدد لها داخل صندوق MMX-BB-1000 أو
    • BB-5000 Series.

    Learn More
  • لوحة تكرارية من النوع المعنون

    المميزات

    •  تدعم ﻧﻔﺲ اﻟﻮﻇﺎﺋﻒ ﻣﺜﻞ اﻟﺸﺎﺷﺔ اﻟﺮﺋﻴﺴﻴﺔ في التحكم لإنذار الحريق ﻣﻦ ﺳﻠﺴﻠﺔ MMX
    •  متوفر منها نوعين
    •  النوع الأول يتكون من شاشة عرض LCD كبيرة خلفية 80 حرف (خط 4 ×  20 حرف).
    •  النوع الثاني يتكون من شاشة عرض LCD كبيرة خلفية 960 حرف (خط 24 ×  40 حرف) لعرض جميع اللغات .
    •  يمكن ربط اللوحة التكرارية مع اي لوحة تحكم في الإنذار فى الشبكة الإنذار لعرض كل اللوحات والتحكم فيها من بعد أو للتحكم في جزء من اللوحات المختارة .
    •  لا تتطلب تعريف نقطة اتصالها على الشبكة بعنوان مستقل.
    •  يسهل استخدام شاشة متكاملة مرتبطة مع أزرار لتحديد الاتجاهات و تحتوى على لوحة مفاتيح أيضا.
    •  تعطى أربعة أنواع من الإشارات وهم ( الإنذار والإشراف و الخلل والمراقبة) لمتابعة الأحداث.
    •  دعم وحدات قابلة للبرمجة .
    •  يعرض RAXN-LCDG تسع أحداث لكل صفحة مع عرض كل حدث على 2 خط * 24 حرف.
    •  يفي  RAXN-LCDG بمتطلبات هيئة  ULC الكندية.
    •  من الممكن تثبيت هذه اللوحات داخل لوحة الإنذار من طراز MMX

    Learn More
Compare