Applications:

The BAVARIA FIRESEARCH is designed with automatic tube sensor, it can work with dry chemical powder or Carbon Dioxide, specifically for protecting inaccessible areas or enclosures which are difficult to access, such as control panels, power panels computer, servers room, main machinery rooms, generators. And is also suitable for protecting cars, buses, boats, ships and fits for use within commercial buildings, industrial plants, residential and fuel station and others.

Download Files

  • Ideal for any application where a potential fire risk is present within an enclosed or confined space by extinguishing fire at its very incipient stage with minimal damage.
  • Firesearch automatic fire extinguishing system  do not need any external source of energy or electric supply.
  • Cost effective as no electrical installation or wiring is required
  • Can be interfaced with an alarm device or system via pressure switch
  • Extinguish Fires Where They Started .... IN 15 SECONDS
  • Detection tube considers all points of an infinite number of sensors and nozzles
  • Available in two systems: Direct Pressure Firesearch and Indirect Pressure Firesearch Systems, with dry chemical powder or Carbon Dioxide
  • Specially designed for protecting inaccessible areas or enclosures such as: vehicles, control panels, storage racks and machinery rooms.
  • Firesearch sensor tube made of flexible engineering polymer material, considers all points of an infinite number of sensors and nozzles.
  • Automatically actuated upon bursting of the tube at any point along its length due to temperature rise upto 100°C
  • Equipped with a special pressure regulator valve innovative to work automatically when the pressure leak from the tube through any hole.
  • Available in two systems: Direct Pressure Firesearch and Indirect Pressure Firesearch Systems.

1. Direct Pressure Operated System

BAVARIA FIRESEARCH direct pressure operated system  uses the firesearch tube as both "Detection Device" a sensor to detect the fire start, and "Extinguishing Agent Delivery System", firesearch tube considers all its points of an infinite number of sensors and nozzles. As the fire starts, the firesearch tube is detected ruptures, forming as an effective nozzle. The pressure will drop releases the cylinder Carbon Dioxide through the effective nozzle to effectively suppress the fire, which allows the fastest extinguishing time and minimum spread of the fire. As an Option the Firesearch system can linked with a sarin alarm operated with battery.

 

2. Indirect Pressure Operated System

BAVARIA FIRESEARCH indirect pressure operated system  uses the firesearch tube as a  "Detection Device" a sensor to detect the fire start only, not as the discharge tube, and "System Activation Device". As the fire starts the firesearch tube ruptures making drop of pressure, effect to active the indirect valve, then causing the Carbon Dioxide is discharged from the cylinder through the diffuser nozzles, which allows the fastest extinguishing time and minimum spread of the fire. As an Option the Firesearch system can linked with a siren alarm operated battery.

 

Discontinue Fires Where They Started ............... IN SECONDS

 

Designed for protecting ....

 

 


BAVARIA FIRESEARCH Dry Chemical Powder DLP (Direct low Pressure)
System's Components:
1 - Head valve with two lines 6 - End of line with manometer
2 - Head valve with one line 7 - Pressure gauge with electrical switch
3 - Extinguishing vessel 8 - Pressure switch
4 - Flexible Firesearch detection tube 9 - Alarm siren
5 - End of line  
   
Head Valve Features:  
  • European Standard EN ISO 10297:2006 Certified
  • Chrome-plated brass valve and internal parts for longer serviceability, available in two head-outlets or one outlet to the flexible sensor tube.
     
Extinguishing Cylinder Features:  
  • Full chrome-plated brass valve and internal parts for longer serviceability, with two firesearch tubes outlets.
  • Equipped with a pressure gauge for instant pressure indication
  • Electricity and corrosion-proof protective base
  • High quality surface treatment and red polyester coating
  • Supplied with a special hanging wall bracket
  • Affords highest extinguishing efficiency due to its special multipurpose BAVARIA  dry chemical powder
Data Specifications
System Type BAVARIA FIRESEARCH DLP ( Direct low Pressure )
Capacity 2 kg 4 kg 6 kg 12 kg
Test Pressure 35 bar
Cylinder Bursting Pressure Over 70 bar
Operating Head Chrome-plated brass valve
Discharge Tube Firesearch polymer flexible tube with several lengths
Shell Material DC 04 Steel according to DIN EN 10130
Tube Bursting Temp. at 8 bar 100 °C (± 5 °C)
Extinguishing Agent MAP-based
Paint Finish Surface treatment and 100% polyester coating
Option at Extra Cost Items 7,8 and 9 (See Fig 1)
 

Indirect Pressure Operated System Dry Chemical Powder (Fig 2)
System's Components:
1 - Head valve 8 - Pressure gauge with electrical switch
2 - Extinguishing vessel 9 - Pressure switch
3 - Steel piping network 10 - Alarm siren
4 - Special diffuser nozzles 11 - Manual release with manometer
5 - Flexible detection tube 12 - Solenoid release
6 - Flexible detection tube 13 - Manual release
7 - End of line with manometer  
   
Head Valve Features:  
  • European Standard EN ISO 10297:2006 Certified
  • Chrome-plated brass valve and internal parts for longer serviceability, available in two head-outlets or one outlet to the flexible sensor tube.
Extinguishing Cylinder Features:  
  • Full chrome-plated brass valve and internal parts for longer serviceability, with two firesearch tubes outlets.
  • Equipped with a pressure gauge for instant pressure indication
  • Electricity and corrosion-proof protective base
  • High quality surface treatment and red polyester coating
  • Supplied with a special hanging wall bracket
  • Affords highest extinguishing efficiency due to its special multipurpose BAVARIA  dry chemical powder

Data Specifications
System Type BAVARIA FIRESEARCH (Indirect low Pressure System)
Capacity 6 kg 12 kg
Test Pressure 35 bar
Cylinder Bursting Pressure Over 70 bar
Operating Head Chrome-plated brass valve
Discharge Fittings Piping net which ends with special nozzle
Shell Material Steel according to DIN EN 10130 and ES 1110
Tube Bursting Temp. at 8 bar 100 °C (± 5 °C)
Extinguishing Agent MAP-based
Paint Finish Surface treatment and 100% polyester coating
Option at Extra Cost Items 8, 9, 10, 11, 12 and 13 (See Fig 2)